Cladding breather membrane: definition and how it works

Y Yves SamamaCreated on 18/12/2023
Cladding breather membrane: definition and how it works

The cladding breather membrane is a key element in making a building weathertight. Are you in the construction field or looking to install a breather membrane for your house? You are in the right place to learn everything you need to know about this technique.

To make you a breather membrane professional, we are going to cover:

  • What is a cladding breather membrane?
  • What is a cladding breather membrane for?

  • What are the different types of cladding breather membrane?

  • How do you choose your breather membrane film?

  • What standards or certifications surround the cladding breather membrane?

  • Laying wooden cladding with a breather membrane: how is it done?

  • Is the cladding breather membrane a durable and effective solution?

  • What risks are there in installing a cladding breather membrane?

  • How do you maintain a cladding breather membrane?

  • Other questions about laying a cladding breather membrane


Laying wooden cladding with a breather membrane, by professionals

What is a cladding breather membrane?

A cladding breather membrane is a waterproof membrane placed under cladding that protects the underlying structure of the building against water and moisture infiltration. By making it possible to avoid rotting wood, mould and other moisture-related problems, it plays an essential role in preserving the integrity of the building.

The cladding breather membrane has the following characteristics:

  • A waterproofing membrane : The cladding breather membrane is made up of a waterproof membrane placed between the external cladding and the structure of the building. This membrane acts as a barrier against water, while allowing water vapour to diffuse through. It thus prevents condensation inside the wall.
  • Drip edge and under-flashing : These elements are generally built into the cladding breather membrane so as to carry water away from the structure. The drip edge is placed above openings, such as windows and doors, to prevent water from getting in. The under-flashing, for its part, is located below openings to collect the water and direct it outwards.

  • Ventilation : The cladding breather membrane is designed to allow ventilation behind the cladding. This helps to prevent condensation and to maintain a healthy atmosphere inside the walls. Good ventilation also encourages rapid drying in the event of water infiltration.
  • Vapour-permeable materials : Some cladding breather membranes use vapour-permeable materials to help moisture diffuse through. This is particularly important in order to avoid condensation forming inside the walls.

What is a cladding breather membrane for?

The breather membrane has many functions, such as protection against water, prevention of condensation, increased durability and the maintenance of structural integrity.

  • Protection against water : The main function of the cladding breather membrane is to protect the structure of the building against water infiltration. It is above all useful in unfavourable weather conditions.

  • Prevention of condensation : By allowing adequate ventilation, the breather membrane helps to prevent condensation inside the walls. It thus reduces the risk of mould and rot.

  • Increased durability : By protecting the structure against moisture-related damage, the cladding breather membrane helps to extend the service life of the building.

  • Maintenance of structural integrity : By avoiding water-related problems, the breather membrane ensures that the structural integrity of the building is maintained. This makes it possible to prevent expensive damage and repairs.

The cladding breather membrane is therefore a central element in the design and construction of buildings. It provides protection against the elements and contributes to the durability of the structure in the long term.

The cladding breather membrane acts as a first line of defence against the weather by preventing rainwater from getting in, while allowing adequate ventilation to avoid condensation.

What are the different types of cladding breather membrane?

There are different types of cladding breather membrane: the flexible cladding breather membrane and the rigid cladding breather membrane. In every case, it is indispensable for protecting your building if you are laying wooden cladding.

The flexible cladding breather membrane

This film, which is impermeable to rain and also permeable to water vapour, is placed under the cladding, before it is laid. Thanks to it, your walls become water-resistant. What is more, the flexible breather membrane protects against wind, guaranteeing complete thermal insulation.

The rigid cladding breather membrane

The rigid cladding breather membrane is made up of wood fibre panels impregnated with latex. It can therefore resist water. Watertight and breathable, these panels also offer acoustic and thermal insulation. Several thicknesses are available, between 22 mm and 140 mm.

How do you choose your cladding breather membrane film?

To choose your cladding breather membrane film, you can refer to the EST classification, drawn up by the Centre Scientifique et Technique du Bâtiment (CSTB, the French building research centre). This classification has three criteria: E for Étanchéité (watertightness), S for resistance to water vapour and T for mechanical strength.

The E classification

To measure watertightness, you have to rely on the EN 13859-1 standard. A membrane bearing the mention E1 or W1 is in the most watertight class. If it is classified E2 or W2, it will be slightly less watertight.

The S classification

The breather membrane has to be permeable to water vapour. The vapour must escape outwards so as to avoid any risk of condensation. Three levels exist in this classification, from the most to the least permeable:

  • Sd1 : this level is equivalent to an air gap — the empty space created between two materials, which insulates against moisture, noise and heat — of 10 cm;

  • Sd2 : the equivalent is an air gap of between 10 and 18 cm;

  • Sd3 : this level represents an air gap of more than 18 cm.

The T classification

This classification is used to measure the ability of the breather membrane to resist tearing and ageing. The further apart the fixing battens are, the greater the resistance has to be.

Three levels exist:

  • Tr1 : it gives resistance suited to battens spaced 45 cm apart;

  • Tr2 : it can withstand a spacing of 60 cm;

  • Tr3 : the resistance can go up to a spacing of 90 cm.

What standards or certifications surround the cladding breather membrane?

Several standards and certifications govern the cladding breather membrane, such as the European standard EN 13859, CE certification and national certifications. These standards and certifications guarantee quality and compliance with industry standards.

The European standard EN 13859 sets the requirements for roofing underlays and cladding breather membranes. Some manufacturers can also obtain specific certifications, such as CE certification (Conformité Européenne). They may also hold national certifications, to attest that their products comply with performance and safety standards.

 Laying a cladding breather membrane on your building

Free, no commitment Describe your project, suppliers reply.

One form, several offers.

  • Two minutes, no account
  • Direct, no middleman
  • Your identity stays private
Describe my project

Laying wooden cladding with a breather membrane: how is it done?

Laying wooden cladding with a breather membrane is done in 6 steps: cleaning the façade, measuring the distance, cutting to size, positioning, unrolling and finishing. The installation is fairly simple but must be faultless. Remember to put a timber framework or battens in place beforehand, so that you can fix your breather membrane.

Let us go back over the 6 steps:

  1. Cleaning the façade : you first have to clean the façade or the timber framework. For this, you have to remove the dust and natural debris that have built up in the walls.

  1. Measuring the distance : you have to measure the distance you will have to cover with the roll of breather membrane, also known as the "width". You can add 10 cm on each side to be on the safe side.

  1. Cutting to size : you have to cut the first roll of cladding breather membrane to the appropriate size. To do this, you can use a knife or scissors.

  1. Positioning : you can then position it in one of the corners of the façade, always putting the printed face towards you. You can now staple it in order to fix it.

  1. Unrolling : it is time to unroll the waterproof film from the top to the bottom of the façade, making sure it is properly taut. If it is, you can staple it all.

  1. Finishing : continue the same process across the whole façade, right to the edges. An overhang of 15 cm can be left on the sides for peace of mind. You can cut them at the last moment.

To make the task easier, remember to equip yourself with the following tools:

  • A tape measure ;

  • A rule ;

  • A pair of scissorsor a knife ;

  • A rain barrier membrane ;

  • A stapler.

It is only after following these steps that you will be able to install your cladding, in wood or in any other material.

Laying a breather membrane after the timber framework

Is the cladding breather membrane a durable and effective solution?

The cladding breather membrane is generally regarded as a durable and effective solution in construction. We are going to set out a few reasons that support this statement:

  • Protection against water infiltration : The cladding breather membrane is designed to act as a protective barrier against water infiltration. It helps to prevent rainwater from getting inside the structure of the building, thus protecting it from moisture.

  • Prevention of condensation : Some breather membranes are designed to allow appropriate ventilation behind the cladding. They thus help to prevent condensation inside the walls. This is essential in order to avoid problems linked to moisture and mould.

  • Improved energy efficiency : By preventing water infiltration and encouraging suitable ventilation, the cladding breather membrane can help to improve the energy efficiency of the building. It limits the heat losses linked to moisture.

  • Protection of the building materials : By creating a water-resistant barrier, the cladding breather membrane helps to extend the service life of the building materials. It protects wood, for example, against rot or decay.

  • Contribution to overall durability : By preserving the structure of the building, the breather membrane can play an essential role in the overall durability of the construction. It reduces maintenance needs and extends the service life of the building.

Despite these many advantages, the effectiveness of the cladding breather membrane depends on various factors. Among them are the quality of the material used (wood, type of wood, wood class, pressure treatment, PVC and so on), correct installation and compliance with building standards.

It is advisable to choose quality products, to follow the manufacturer’s recommendations and above all to ensure a proper installation, so as to guarantee the long-term performance of the cladding breather membrane.

What risks are there in installing a cladding breather membrane?

An inappropriate or faulty installation of the cladding breather membrane can have serious consequences for the durability and the health of the building. Water infiltration can lead to rotting wood, corrosion of the metal structure or the formation of mould.

This can compromise the structural integrity of the building, lead to expensive repairs and potentially affect the health of the occupants by creating an environment favourable to the growth of harmful mould.

A correct installation is therefore crucial to guaranteeing the long-term performance of the cladding breather membrane and the overall durability of the building. What is more, maintaining the breather membrane remains paramount to ensuring its durability and its effectiveness in the long term.

Installing a breather membrane on your house

How do you maintain a cladding breather membrane?

To ensure that a cladding breather membrane is properly maintained, we can give you the following advice:

  • Carry out a regular inspection : this will make it possible to detect damage;

  • Repair any damage : damaged areas have to be repaired quickly;

  • Clean carefully : if debris, leaves or other materials build up on the cladding breather membrane, you have to clean them off carefully so as to avoid any damage;

  • Make sure the joints are properly sealed : if needed, you can use suitable sealing products to reinforce the joints and prevent water infiltration;

  • Check the fixing of the cladding breather membrane regularly : to make sure that the fixings are in good condition and properly attached to the structure of the building.

  • Take precautions to avoid any accidental damage : during other building or renovation projects, for example;

  • Consult the recommendations of the cladding breather membrane manufacturer : find out about maintenance, repairs and any replacements;

  • Make sure the water drainage elements are in good condition and correctly positioned : if the maintenance is carried out by professionals, you have to make sure they are trained in the maintenance practices specific to the type of cladding breather membrane installed at your property.

Other questions about laying a cladding breather membrane

Is the cladding breather membrane compulsory?

Yes, the breather membrane for a timber framework is compulsory. It is indispensable for every type of cladding: wooden or composite cladding, PVC, metal and so on. When façades are not weathertight, laying a cladding breather membrane proves indispensable. If it is open-jointed cladding, the breather membrane has to be UV-resistant, because UV rays can get in between the weatherboards.